高度近视眼后房型ICL植入术后波前像差的改变
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

基金项目:

辽宁省教育厅重点实验室项目(No.2009S107); 辽宁省科技厅科技攻关项目(No.2010225034)


Wave-front aberration changes in high myopia patients after implantable collamer lens implantation
Author:
Affiliation:

Fund Project:

Key Laboratory Project of Liaoning Provincial Education Bureau, China(No. 2009S107); Scientific and Technological Project of Liaoning Provincial Science and Technology Bureau, China(No. 2010225034)

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    目的:观察高度近视眼有晶状体眼后房型人工晶状体植入后全眼及眼内波前像差的变化。

    方法:选择行有晶状体眼人工晶状体(implantable collamer lens,ICL)植入术的高度近视眼患者25例50眼,用尼德克波前像差仪测量患者6mm瞳孔区域内术前和术后1mo的波前像差值,对其进行配对t检验。

    结果:ICL植入眼术后1mo全眼总体波前像差(OPD Total)、眼内总体波前像差(Internal Total)较术前明显下降(P<0.05)。全眼总体高阶波前像差(OPD High)、全眼总体球面像差(OPD T.SPH)、全眼总体彗差(OPD T.Coma)、全眼总体三叶草(OPD T.Trefoil)、眼内总体彗差(Internal T.Coma)较术前有不同程度升高,具有统计学意义(P<0.05)。角膜总体波前像差(C-Total)、角膜总体高阶波前像差(C-High)、角膜球差(C-T.Sph)、角膜彗差(C-T.Coma)、角膜四叶草(C-T.4Foil)较术前有不同程度升高,角膜三叶草(C-T.Trefoil)较术前明显下降,但差异均无统计学意义。

    结论:有晶状体眼后房型人工晶状体植入术虽然显著降低了高度近视眼的总体波前像差,但术眼球面像差、彗差、三叶草等高阶波前像差有不同程度增加。

    Abstract:

    AIM: To observe the changes of wave-front aberration in high myopia patients after implantable collamer lens(ICL)implantation.

    METHODS: Wave-front aberrations were evaluated by NIDEK Optical path differences(OPD)in 50 eyes of 25 high myopia patients who received ICL implantation preoperatively and 1 month postoperatively. The results were analyzed by Student's t test.

    RESULTS:The Zernike functional values of total aberration and internal total aberration in 6mm pupil size area of the postoperative eyes implanted with ICL were found significantly statistical lower(P<0.05)than those of the preoperative eyes. The Zernike functional values of total high-order aberration, total spherical-like aberration, total coma-like aberration, total trefoil-like aberration and internal total coma-like aberration were found significantly statistical higher(P<0.05)than those of the preoperative eyes. The Zernike functional values of cornea aberration were not found significantly statistical changes compared with those of the preoperative eyes.

    CONCLUSION: Although total aberrations could be decreased by implantable collamer lens implantation in high myopia eyes, high-order aberrations such as total spherical-like aberrations, total coma-like aberrations and total trefoil-like aberrations are increased in certain degree.

    参考文献
    相似文献
    引证文献
引用本文

刘玉璞,李雪冬,鲁媛媛,等.高度近视眼后房型ICL植入术后波前像差的改变.国际眼科杂志, 2013,13(3):462-465.

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2012-12-10
  • 最后修改日期:2013-03-05
  • 录用日期:
  • 在线发布日期:
  • 出版日期: