硅油填充眼在不同时机行人工晶状体植入的屈光误差比较
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

基金项目:


Comparison of refractive error in eyes with vitrectomy, silicone oil tamponade finished phacoemulsification and intraocular lens implantation in different time point
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    目的:比较玻璃体切割硅油填充眼不同时机行白内障超声乳化并人工晶状体植入术后屈光误差。

    方法:回顾性分析选取2009-01/2011-12玻璃体切割硅油填充眼不同时机行白内障超声乳化并人工晶状体植入术51例51眼,其中A组17例行玻璃体切割硅油填充联合白内障超声乳化并人工晶状体植入术,术后3~6mo行硅油取出; B组13例行玻璃体切割术后硅油取出联合白内障超声乳化并人工晶状体植入术,C组21例硅油取出术后择期行白内障超声乳化并人工晶状体植入术,比较术后3mo时屈光误差情况。

    结果:三组平均绝对屈光误差值分别为(0.873±0.256)D,(0.828±0.134)D,(0.473±0.121)D,A组和B组之间差异无统计学意义(P>0.05),C组和A组及B组之间差异有统计学意义(P<0.05)。

    结论:A超眼轴测量计算人工晶状体度数,玻璃体切割硅油填充眼在取油后择期行白内障超声乳化并人工晶状体植入术屈光误差小。

    Abstract:

    AIM: To compare the refractive error in eyes with vitrectomy and silicone oil tamponade finished phacoemulsification and intraocular lens(IOL)implantation in different time point.

    METHODS: Fifty-one patients(51 eyes)with vitrectomy and silicone oil tamponade performed phacoemulsification and IOL implantation were retrospectively analysed during 2009-01/2011-12 and divided into three groups by different time point of phacoemulsification and IOL implantation. There were 17 cases in A group performed silicone oil tamponade after vitrectomy combined with phacoemulsification and intraocular lens IOL implantation, silicone oil removal was performed after 3-6 months; 13 cases in B group performed silicone oil removal combined with phacoemulsification and IOL implantation; 21 cases in C group of scheduled phacoemulsification and IOL implantation after silicone oil removal, refractive error was compared 3months postoperatively.

    RESULTS: The average absolute value of refractive error was 0.873±0.256D in A group, 0.828±0.134D in B group, 0.473±0.121D in C group. There was no statistical significant difference compared with A group and B group(P>0.05), but there was statistical significant difference compared with C group and A, B group(P<0.05).

    CONCLUSION: Axial length was measured by A Scan ultrasonograph. The refractive error was small in group of phacoemulsification and IOL implantation after silicone oil removal relatively.

    参考文献
    相似文献
    引证文献
引用本文

石芊,彭秀军,刘百臣,等.硅油填充眼在不同时机行人工晶状体植入的屈光误差比较.国际眼科杂志, 2013,13(6):1206-1208.

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2013-01-16
  • 最后修改日期:2013-05-24
  • 录用日期:
  • 在线发布日期: 2013-06-03
  • 出版日期: