小切口透镜取出术和Q值引导角膜屈光术的生物力学比较
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

基金项目:

杭州市科技发展计划项目(No.20140633B44)


Comparison of the corneal biomechanical effects after small-incision lenticule extraction and Q value guided femtosecond laser-assisted laser in situ keratomileusis
Author:
Affiliation:

Fund Project:

Science and Technology Development Plan Project of Hangzhou(No.20140633B44)

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    目的:比较全飞秒小切口透镜取出术(small-incision lenticule extraction,SMILE)与Q值引导飞秒辅助原位角膜磨镶术(femtosecond laser-assisted laser in situ keratomileusis,FS-LASIK)治疗近视眼术后患者角膜生物力学特性的变化,以探讨两种术式的生物力学稳定性,为临床术式的选择提供客观依据。

    方法:采用前瞻性临床研究方法,选择我院进行SMILE或Q值引导FS-LASIK的近视及近视散光患者102例200眼,其中SMILE组51例100眼,Q值引导FS-LASIK组51例100眼,分别于术前及术后1d,2wk,1、3mo使用眼反应分析仪(ocular response analyzer,ORA)测量角膜黏滞力(corneal hysteresis,CH)和角膜阻力因子(corneal resistance factor,CRF)。

    结果:SMILE组与Q值引导FS-LASIK组手术前后CH和CRF均较术前降低(P<0.01),然而术后各时间点间差异无统计学意义(P>0.05)。SMILE组与Q值引导FS-LASIK组手术前与术后各时间点CH和CRF变化量的差异无统计学意义(P>0.05)。

    结论:SMILE与Q值引导FS-LASIK都会引起角膜生物力学特性的降低,且术后1d生物力学特性即趋于稳定。此外,Q值引导FS-LASIK与无瓣SMILE对角膜生物力学特性的改变无显著差异。

    Abstract:

    AIM:By comparing the changes of biomechanical properties of the cornea after small-incision lenticule extraction(SMILE)and those after Q value guided femtosecond laser-assisted laser in situ keratomileusis(FSLASIK), to study the stability of biomechanical properties of the cornea after these two kinds of surgery and provide objective data for clinical operation.

    METHODS: Prospective comparative cases. One hundred and two cases(200 eyes)with myopia and myopic astigmatism were divided into 2 groups, 51 cases(100 eyes)for SMILE, and 51 cases(100 eyes)for Q value guided FS-LASIK. Corneal hysteresis(CH)and the corneal resistance factor(CRF)were quantitatively assessed with the Ocular Response Analyzer(ORA)preoperatively and 1d, 2wk, 1 and 3mo postoperatively.

    RESULTS: The decrease in CH and the CRF were statistically significant in both groups(P<0.01). However, the changes subsequently stabilized with no further deterioration(P>0.05). There were no statistically significant differences between the biomechanical changes in the two groups at any time(P>0.05).

    CONCLUSION: Both SMILE and Q value guided FS-LASIK can cause biomechanical decreases in the cornea. After 1d postoperatively, the decreases are nearly stable. There are no significant differences between the effect of SMILE and Q value guided FS-LASIK on the biomechanical properties of the cornea.

    参考文献
    相似文献
    引证文献
引用本文

张君,郑历,童蟾素,等.小切口透镜取出术和Q值引导角膜屈光术的生物力学比较.国际眼科杂志, 2016,16(4):638-641.

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2015-11-13
  • 最后修改日期:2016-03-16
  • 录用日期:
  • 在线发布日期: 2016-03-28
  • 出版日期: