角膜塑形镜的偏心对眼轴及视觉质量的影响
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

基金项目:


Effect of eccentricity of overnight orthokeratology lenses on axial growth and visual quality
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    目的:探讨角膜塑形(OK)镜片的偏心度对眼轴和视力质量的影响。

    方法:根据OK镜片偏心程度,将患者分为三组:低偏心度组(偏心度≤0.5 mm),中偏心度组(0.5<偏心度≤1.0 mm)和高偏心度组(1<偏心度≤1.5 mm)。分析配戴OK镜后OK镜偏心程度、球面等效球镜度(SE)、未矫正视力(UCVA)、配戴OK镜前后眼轴长度(AL)、3 mm瞳孔下的总高阶像差(HOA)、彗差和球面像差(SA)。三组间各指标差异使用Kruskal-WallisH Rank分析。

    结果:回顾性分析75例139眼。在低偏心组(53眼)中,平均年龄为(11.4±2.4)a,SE为(-3.24±1.48)D,AL为(24.85±1.01)mm; 中偏心组(53眼),平均年龄(11.4±2.2)a,SE为(-3.22±1.29)D,AL为(25.15±0.92)mm; 在高偏心组(31眼)中,平均年龄为(11.5±1.9)a,SE为(-3.54±1.43)D,AL为(24.95±0.84)mm。2a后,三组间眼轴的变化无显着性差异(P=0.089)。高偏心组HOA、SA、彗差明显高于中偏心组、低偏心组(P<0.05)。

    结论:OK镜配戴过程中没有必要严格要求镜片位置的绝对居中。镜片不必要的调整可能会延迟眼轴控制。另外,眼轴控制与视觉质量之间的平衡关系应进一步探讨评估。

    Abstract:

    AIM:To explore the effect of eccentricity of overnight orthokeratology(OK)lenses on 2-year eye axial growth and visual quality.

    METHODS:Based on the degree of eccentricity of OK lenses, patients were divided into three groups: a low degree of eccentricity group(degree of eccentricity ≤0.5 mm), a group of moderate eccentricity(eccentric degree >0.5-≤1.0 mm)and a group with a high degree of eccentricity(eccentric degree >1-≤1.5 mm). The degree of eccentricity of the OK lens, spherical equivalent(SE), the uncorrected visual acuity after wearing OK lenses(UCVA), axial length before and after wearing OK lenses(AL), total higher-order aberrations(HOA), comas, and spherical aberrations(SA)for 3 mm pupils were analyzed. The difference among the three groups for all parameters was compared using the Kruskal-Wallis H Rank-Sum test.

    RESULTS:The study retrospectively analyzed 75 cases(139 eyes). In the low eccentricity group(53 eyes), the mean age was 11.4±2.4 years, SE was -3.24±1.48 D, and AL was 24.85±1.01 mm. In the moderate eccentricity group(53 eyes), the mean age was 11.4±2.2 years, SE was -3.22±1.29 D, and AL was 25.15±0.92 mm. In the high eccentricity group(31 eyes), the mean age was 11.5±1.9 years, SE was -3.54±1.43 D, and AL was 24.95±0.84mm. After two years, there was no significant difference in the changes of the axis among the three groups(P=0.089). The HOA, SA, and coma in the high eccentric group were significantly higher than in the middle eccentric group(P<0.05). The HOA, SA, and coma in the high eccentric group were also significantly higher than those in the low eccentric group(P<0.05).

    CONCLUSION:For OK lenses, it is unnecessary to strictly require the absolute centralization of the lens position. An unnecessary change of the lenses may delay the eye-axis control. However, the balance between axial control and visual quality should be assessed.

    参考文献
    相似文献
    引证文献
引用本文

Chen ZY, Ye ZD, Zhang Y, Hu YH. Effect of eccentricity of overnight orthokeratology lenses on axial growth and visual quality. Guoji Yanke Zazhi(Int Eye Sci) 2020;20(12):2023-2027

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2019-12-29
  • 最后修改日期:2020-09-09
  • 录用日期:
  • 在线发布日期: 2020-11-19
  • 出版日期: