Corneal white-to-white distance and mesopic pupil diameter
Author:
Contact Author:

Affiliation:

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    AIM: To study the relationship between corneal white-to-white (WTW) distance and mesopic pupil diameter. METHODS: This study is composed of 30 cases that underwent photorefractive keratotomy (PRK). Pupil size measurements were performed with Schwind ORK wavefront analyzer in mesopic conditions. WTW distance was measured with a measuring caliper. Also, A-scan ultrasound examination was performed in all patients. The relationship among the mesopic pupil diameter and age, sex, axial length, lens thickness, anterior chamber depth(ACD), horizontal WTW distance, vertical WTW distance, spherical equivalent, and average keratometry were analyzed with univariate and multivariate regression analysis. RESULTS: Mean pupil diameter was (6.39±0.80)mm (range: 3.70mm-7.73mm). Horizontal WTW distance measurements were between 11.00mm and 12.50mm and mean horizontal WTW distance was (11.79±0.43)mm. On the other hand, vertical WTW distances ranged between 10.00mm and 13.00mm, and their mean was (11.42±0.72)mm. Bivariate correlation between pupil diameter and other variables showed that the axial length, ACD, spherical equivalent, and horizontal WTW distance had a moderate correlation with mesopic pupil diameter. Multiple regression analysis revealed that spherical equivalent and horizontal WTW distances were significantly associated with mesopic pupil diameter (R=0.598, R2=0.358 P=0.02). CONCLUSION: This study shows that mesopic pupil diameter is closely related to horizontal WTW distance. These two factors must be taken in consideration together in preoperative ablation zone planning.

    Reference
    Related
    Cited by
Get Citation

Hasan Basri Cakmak, Nurullah Cagil, Huseyin Simavli, et al. Corneal white-to-white distance and mesopic pupil diameter. Int J Ophthalmol, 2012,5(4):505-509

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:June 21,2011
  • Revised:May 26,2012
  • Adopted:
  • Online:
  • Published: