Evaluation of immersion 20 MHz B-scan ultrasonography in observing lens in the alkali burn eyes
Author:
Contact Author:

Affiliation:

Department of Ophthalmology, Chinese People''s Liberation Army General Hospital, Beijing 100853,China

Clc Number:

Fund Project:

Foundations: Supported by National Key Basic Research Program of China (973 Program, No.2013CB967001); National Natural Science Foundation of China (No.81271052, No.31271059).
Conflicts of Interest: Yang QH, None; Chen B, None; Wang LQ, None; Li ZH, None; Huang YF, None.
ACKNOWLEDGEMENTS The authors want to thank Zhang MN, MD for his careful reading of the manuscript and his useful comments and suggestions.

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    AIM:To evaluate the accuracy of 20 MHz immersion B-scan ultrasonography in observing lens and to investigate the value of this noninvasive preoperative diagnosis method in alkali burn eyes.METHODS: It was a comparative study. Fifty-six cases (56 eyes) of alkali burn eyes were examined by ultrasound biomicroscopy (UBM) and immersion 20 MHz B-scan ultrasonography from June 2011 to April 2013, the images were analyzed, and the ultrasonographic diagnosis compared with the operation results.RESULTS: In 56 alkali burn eyes examined by UBM, the lens were not detected in 16 eyes; the IOL could be detected in 2 eyes; the anterior lens capsule surface or/and the front lens could be detected in 18 eyes, and lens opacification in 3 eyes of them; suspected abnormal lens were detected in the other 20 eyes. In all the same eyes examined by immersion 20 MHz B-scan ultrasonography, the lens were not detected in 16 eyes; the IOL could be detected in 2 eyes; 24 abnormal lens (opacity, lens expansion, shrinkage) and 14 normal lens were found. Compared with the intraoperative findings, the diagnostic accordance rate of the immersion 20 MHz B-scan appearance of lens was 100% (56/56), which was significantly higher than examined by UBM 57.14% (32/56) (χ2=30.55, P=0.0000).CONCLUSION:Immersion 20 MHz B-scan ultrasonography can observe the lens accurately in alkali burn eyes. It has important clinical value to combine with UBM in eyes of alkali burn.

    Reference
    Related
    Cited by
Get Citation

Qing-Hua Yang, Bing Chen, Li-Qiang Wang, et al. Evaluation of immersion 20 MHz B-scan ultrasonography in observing lens in the alkali burn eyes. Int J Ophthalmol, 2014,7(4):632-637

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:December 22,2013
  • Revised:May 04,2014
  • Adopted:May 04,2014
  • Online: August 15,2014
  • Published: