Comparison of corneal flaps created by Wavelight FS200 and Intralase FS60 femtosecond lasers
Author:
Contact Author:

Yue-Hua Zhou. Ophthalmic Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology & Visual Sciences Key Lab, No.1 Dongjiaomin Ln, Dongcheng District, Beijing 100730, China. shouyiliuqian@163.com

Affiliation:

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    AIM: To assess and compare the morphology of corneal flaps created by the Wavelight FS200 and Intralase FS60 femtosecond lasers in laser in situ keratomileusis (LASIK). METHODS: Four hundred eyes of 200 patients were enrolled in this study and divided into Wavelight FS200 groups (200 eyes) and Intralase FS60 groups (200 eyes). Fourier-domain optical coherence tomography (RTVue OCT) was used to measure the corneal flap thickness of 36 specified measurements on each flap one week after surgery. Results were used to analyze the regularity, uniformity and accuracy of the two types of LASIK flaps. RESULTS: The mean thickness of corneal flap and central flap was 105.71±4.72 μm and 105.39±4.50 μm in Wavelight FS200 group and 109.78±11.42 μm and 109.15 ±11.59 μm in Intralase FS60 group, respectively. The flaps made with the Wavelight FS200 femtosecond laser were thinner than those created by the Intralase FS60 femtosecond laser (P=0.000). Corneal flaps in the 2 groups were uniform and regular, showing an almost planar configuration. But the Wavelight FS200 group has more predictability and uniformity of flap creation. The mean deviation between achieved and attempted flap thickness was smaller in the Wavelight FS200 group than that in the Intralase FS60 group, which were 5.18±3.71 μm and 8.68±7.42 μm respectively. The deviation of more than 20 µm was 0.2% measurements in Wavelight FS200 group and 8.29% measurements in Intralase FS60 group. CONCLUSION: The morphologies of flaps created by Wavelight FS200 are more uniform and thinner than those created by Intralase FS60.

    Reference
    Related
    Cited by
Get Citation

Qian Liu, Yue-Hua Zhou, Jing Zhang, et al. Comparison of corneal flaps created by Wavelight FS200 and Intralase FS60 femtosecond lasers. Int J Ophthalmol, 2016,9(7):1006-1010

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:January 31,2015
  • Revised:August 26,2015
  • Adopted:
  • Online: July 12,2016
  • Published: