Selective laser trabeculoplasty in pseudophakic and phakic eyes: a prospective study
Received:April 12, 2016  Revised:July 25, 2016
Email this Article  Add to Favorites  Print
DOI:10.18240/ijo.2017.04.15
Key Words:: mechanism of trabeculoplasty  selective laser trabeculoplasty  pseudophakes versus phakic eyes  open angle glaucoma  pressure lowering after lens extraction
Fund Project:
        
AuthorInstitution
Myrjam De Keyser Department of Medicine, University of Antwerp, Univer-siteitsplein, Antwerp B-2610, Belgium
Maya De Belder Department of Experimental Psychology, Faculty of Psychology and Education, Ghent University, Henri Dunantlaan, Ghent B-9000, Belgium
Veva De Groot Department of Medicine, University of Antwerp, Univer-siteitsplein, Antwerp B-2610, Belgium; Department of Ophthalmology, Antwerp University Hospital, Wilrijkstraat, Edegem B-2650, Belgium
Hits: 780
Download times: 158
Abstract:
      AIM: To compare the efficacy of selective laser trabeculoplasty (SLT) in replacing medical therapy in pseudophakic and phakic eyes.

    METHODS: Subgroup of a prospective randomized clinical trial including patients with primary open angle glaucoma or ocular hypertension controlled with medication. Of 38 pseudophakic eyes were matched with 38 phakic eyes. SLT was offered as a way to decrease medication while maintaining the same low eye pressure. SLT was performed over 360°, at 3ns, spotsize 400 ?m, 100 spots. Data [intraocular pressure (IOP), number of medications needed] were measured at 1h, 1wk, 1, 3, 6 and 12mo. An independent-samples t-test was performed to compare baseline characteristics of the phakic and the pseudophakic group and differences in evolution of mean IOP and number of used medications. Chi-squared analysis was performed to investigate proportions of fast, slow and non-responders.

    RESULTS: The mean IOP measurement was 13.00± 2.88 mm Hg in the phakic group (38 eyes) and 13.51±

    CONCLUSION: IOP lowering effect of SLT is comparable between phakic and pseudophakic eyes.