Consistent comparison of angle Kappa adjustment between Oculyzer and Topolyzer Vario topography guided LASIK for myopia by EX500 excimer laser
Author:
Contact Author:

Feng-Ju Zhang. Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology & Visual Sciences Key Lab, Beijing 100730, China. wxw93@hotmail.com

Affiliation:

Clc Number:

Fund Project:

Supported by 215 High Level Talent Fund of Beijing Health Government (No.2013-2-023).

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    AIM: To evaluate and compare the uniformity of angle Kappa adjustment between Oculyzer and Topolyzer Vario topography guided ablation of laser in situ keratomileusis (LASIK) by EX500 excimer laser for myopia. METHODS: Totally 145 cases (290 consecutive eyes )with myopia received LASIK with a target of emmetropia. The ablation for 86 cases (172 eyes) was guided manually based on Oculyzer topography (study group), while the ablation for 59 cases (118 eyes) was guided automatically by Topolyzer Vario topography (control group). Measurement of adjustment values included data respectively in horizontal and vertical direction of cornea. RESULTS: Horizontally, synclastic adjustment between manually actual values (dxmanu) and Oculyzer topography guided data (dxocu) accounts 35.5% in study group, with mean dxmanu/dxocu of 0.78±0.48; while in control group, synclastic adjustment between automatically actual values (dxauto) and Oculyzer topography data (dxocu) accounts 54.2%, with mean dxauto/dxocu of 0.79±0.66. Vertically, synclastic adjustment between dymanu and dyocu accounts 55.2% in study group, with mean dymanu/dyocu of 0.61±0.42; while in control group, synclastic adjustment between dyauto and dyocu accounts 66.1%, with mean dyauto/dyocu of 0.66±0.65. There was no statistically significant difference in ratio of actual values/Oculyzer topography guided data in horizontal and vertical direction between two groups (P=0.951, 0.621). CONCLUSION: There is high consistency in angle Kappa adjustment guided manually by Oculyzer and guided automatically by Topolyzer Vario topography during corneal refractive surgery by WaveLight EX500 excimer laser.

    Reference
    Related
    Cited by
Get Citation

Ming-Shen Sun, Li Zhang, Ning Guo, et al. Consistent comparison of angle Kappa adjustment between Oculyzer and Topolyzer Vario topography guided LASIK for myopia by EX500 excimer laser. Int J Ophthalmol, 2018,11(4):662-667

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:August 15,2017
  • Revised:January 18,2018
  • Adopted:
  • Online: April 10,2018
  • Published: