Ocular surface heat effects on ocular hemodynamics detected by real-time measuring device
Author:
Contact Author:

Xin-Rong Zhou. Department of Ophthalmology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200080, China. zhouxrhmu@126.com; Long-Qiu Li. Key Laboratory of Micro-systems and Microstructures Manufacturing of Ministry of Education, Harbin Institute of Technology, Harbin 150000, Heilongjiang Province, China. longqiuli@hit.edu.cn; Min Ren. Department of Ultrasound, Shanghai First Maternity and Infant Hospital, Tongji University School of Medicine, Shanghai 200080, China. dochrm@163.com

Affiliation:

Clc Number:

Fund Project:

Supported by the National Natural Science Funds for Young Scholar (No.81400394); Heilongjiang Province Science Foundation for Youths (No.QC08C97); Research Fund for the Doctoral Program of the Second Affiliated Hospital of Harbin Medical University (No.BS2008-23).

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    AIM: To investigate the ocular hemodynamic effects of applying a hot compress to the eye. METHODS: The right eyes of five New Zealand white rabbits, both male and female, were hot-compressed for 18min. An independently designed novel ocular contact-type temperature measuring device was used to measure the ocular surface temperature before and after the heating. Relevant retrobulbar hemodynamic parameters such as peak systolic velocity (PSV), end diastolic velocity (EDV), and resistance index (RI) of each of the central retinal artery (CRA), long posterior ciliary artery (LPCA), and ophthalmic artery (OA), as well as the mean velocity (Vm) of the central retinal vein (CRV), were measured using a color Doppler flow imaging (CDFI) technique and expressed as mean values with standard deviation (mean±SD). A statistical analysis was conducted based on a paired t-test and the Wilcoxon signed-rank test. RESULTS: The employed real-time temperature measuring device was able to accurately measure ocular surface temperature during the hot-compress process. The temperature increased after the hot compress was applied. Analysis showed that the PSV and EDV values of the CRA and LPCA significantly increased after the application of the hot compress, as did the Vm of the CRV. There were no significant changes in the EDV of the OA nor the RI of each artery. CONCLUSION: This experiment, which is the first of its kind, confirms that the retrobulbar blood flow velocities can increase upon heating the ocular surface. This simple method may be useful in the future.

    Reference
    Related
    Cited by
Get Citation

Ting-Ting Li, Guang-Bin Shao, Yu-Long Jiang, et al. Ocular surface heat effects on ocular hemodynamics detected by real-time measuring device. Int J Ophthalmol, 2018,11(12):1902-1908

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:January 23,2018
  • Revised:October 15,2018
  • Adopted:
  • Online: December 05,2018
  • Published: