Citation:Lorente-Velázquez A,García-Montero M,Gómez-Sanz FJ,Viejo LRd,Hernández-Verdejo JL,Madrid-Costa D.Comparison of the impact of nesofilcon A hydrogel contact lens on the ocular surface and the comfort of presbyopic and non-presbyopic wearers.Int J Ophthalmol 2019;12(4):640-646,doi:10.18240/ijo.2019.04.19
Comparison of the impact of nesofilcon A hydrogel contact lens on the ocular surface and the comfort of presbyopic and non-presbyopic wearers
Received:July 24, 2018  Revised:December 13, 2018
Email this Article  Add to Favorites  Print
DOI:10.18240/ijo.2019.04.19
Key Words:nesofilcon A hydrogel material; ocular surface parameters; presbyopia; multifocal daily contact lenses
Fund Project:
                 
AuthorInstitution
Amalia Lorente-Velázquez Department of Optometry and Vision, Faculty of Optics and Optometry, Complutense University of Madrid, Madrid 28037, Spain
María García-Montero Department of Optometry and Vision, Faculty of Optics and Optometry, Complutense University of Madrid, Madrid 28037, Spain
Francisco Javier Gómez-Sanz Department of Optometry and Vision, Faculty of Optics and Optometry, Complutense University of Madrid, Madrid 28037, Spain
Laura Rico del Viejo Department of Optometry and Vision, Faculty of Optics and Optometry, Complutense University of Madrid, Madrid 28037, Spain
José Luis Hernández-Verdejo Department of Optometry and Vision, Faculty of Optics and Optometry, Complutense University of Madrid, Madrid 28037, Spain
David Madrid-Costa Department of Optometry and Vision, Faculty of Optics and Optometry, Complutense University of Madrid, Madrid 28037, Spain
Hits: 336
Download times: 24
Abstract:
      AIM: To assess and compare the impact of a daily disposable contact lens (CL) with high water content on the ocular surface and comfort of the presbyopic and non-presbyopic population after one day of use.

    METHODS: Totally 20 presbyopes and 30 non-presbyopes non-contact wearers were fitted with nesofilcon A CLs. CL thickness was measured to assess material stability during daily wear, and ocular surface parameters were also assessed. Optical quality was analyzed for all cases. In addition, CL comfort was rated.

    RESULTS: No significant differences were found in CL thickness, tear film osmolarity, average tear break-up time, bulbar redness, central corneal thickness, corneal volume, root-mean-square of higher-order aberrations (RMS of HOAs) and vertical and horizontal coma, either as a function of the group or time of use. A significant decrease in tear meniscus height and first break-up of the tear film was found in the presbyopic group (P=0.038; P=0.007 respectively). A decrease in spherical aberration coefficient was found after CL insertion (P=0.031 monofocal CL; P=0.023 low addition multifocal CL; P=0.016 high addition multifocal CL). Multifocal CL were thicker than monofocal CL (P=0.045). Comparison between groups showed more discomfort in presbyopes than non-presbyopes (P=0.003).

    CONCLUSION: This study evidence that the behavior of the daily disposable CL with high water content seems to be stable during the day of use. Ocular parameters measured during wear show that CL behavior is the same for presbyopes and non-presbyopes, being more uncomfortable for presbyopes.

PMC FullText Html:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6469564/