Reproducibility of macular perfusion parameters in non-proliferative diabetic retinopathy patients by two different OCTA sweep modes
Author:
Contact Author:

Yan-Long Bi. Department of Ophthalmology, Tongji Hospital Affiliated to Tongji University School of Medicine, Shanghai 200065, China. biyanlong@tongji.edu.cn

Affiliation:

Clc Number:

Fund Project:

Supported by National Natural Science Foundation of China (No.82070920); Major Clinical Research Projects of the Three-Year Action Plan for Promoting Clinicial Skills and Clinical Innovation in Municipal Hospitals (No.SHDC2020CR1043B-010).

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    AIM: To assess the reproducibility of macular perfusion parameters in non-proliferative diabetic retinopathy (NPDR) patients measured by different examiners and two different sweep modes of optical coherence tomography angiography (OCTA). METHODS: Ninety-eight (98 eyes) patients with NPDR were included in this study. All participates were performed three times using Cirrus OCTA with Angiography 3×3 mm2 and 6×6 mm2 sweep mode by two examiners. The macular foveal avascular zone (FAZ) and vessel density (VD) in the superficial retinal layer (SRL) were measured. The reproducibility of the measurements was evaluated with intraclass correlation coefficients (ICC) and coefficient of variation (CoV). RESULTS: The intra-mode ICCs of Angiography 3×3 mm2 and 6×6 mm2 sweep mode were 0.957 to 0.959 and 0.964 to 0.977, respectively; and the inter-mode ICCs were 0.962 to 0.970. The intra-examiner ICCs of macular perfusion parameters were >0.950; and the inter-examiner ICCs were 0.928 to 0.969. All CoVs were <1.0%. CONCLUSION: Cirrus OCTA can measure macular perfusion parameters in NPDR patients with excellent reproducibility. The measurements of FAZ and VD in the SRL determined by Angiography 3×3 mm2 and 6×6 mm2 sweep mode are highly consistent and both sweep modes are suitable for macular perfusion parameters measurement.

    Reference
    Related
    Cited by
Get Citation

Shen Qu, Ao Rong, Yun-Li Niu, et al. Reproducibility of macular perfusion parameters in non-proliferative diabetic retinopathy patients by two different OCTA sweep modes. Int J Ophthalmol, 2022,15(9):1483-1487

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:July 02,2021
  • Revised:September 09,2021
  • Adopted:
  • Online: September 01,2022
  • Published: