A modified 3D stereophotogrammetry-based distraction test for assessing lower eyelid tension
Author:
Contact Author:

Yong-Wei Guo. Eye Center, Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou 310009, Zhejiang Province, China; Ludwig M. Heindl. Department of Ophthalmology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne 50937, Nordrhein-Westfalen, Germany. yongwei-guo@zju.edu.cn; ludwig.heindl@uk-koeln.de

Affiliation:

Clc Number:

Fund Project:

Supported by the Project of National Key Research and Development (No.2018YFC1106103); Chongqing Science and Health Joint Medical Research Project-Youth Project (No.2022QNXM016); The Fundamental Research Funds for the Central Universities (No.2021FZZX005-15).

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    AIM: To investigate the reliability of a modified three-dimensional distraction test (3D-DT) and three-dimensional pinch test (3D-PT) for assessing lower eyelid tension (LET). METHODS: A cross-sectional study was conducted among 97 volunteers including 97 eyelids with no history of trauma, tumor, or reconstructive surgeries. Six three-dimensional photographs were acquired for each participant, including two photographs obtained in a neutral position (NP), two using a modified 3D-DT with a 15.9-grammes stainless steel eyelid hook performed, and two using 3D-PT. RESULTS: The mean absolute differences between NP, 3D-DT, and 3D-PT measurements varied between 0.07 and 7.42, 0.10 and 13.10, and 0.07 and 15.97, respectively; technical error of measurement varied between 0.05 and 7.81, 0.09 and 10.19, and 0.07 and 12.47, respectively; and relative error measurements varied between 0.10% and 11.50%, 0.16% and 30.51%, and 0.11% and 38.75%, respectively. For intra-rater reliability, the intraclass correlation coefficients (ICCs) were more than 0.80 in seven out of eight measurements obtained in the NP and 3D-DT, whereas those obtained in the 3D-PT were as low as less than 0.30 by rater 1; the ICCs of all the measurements obtained in all the positions (NP, 3D-DT, and 3D-PT) were more than 0.80 by rater 2. For inter-rater reliability six out of eight NP and 3D-DT measurements had an ICC greater than 0.80, whereas those of 3D-PT measurements were less than 0.30. For intra-method reliability, the ICCs of all the NP measurements were more than 0.87, whereas those of the six 3D-DT measurements and four 3D-PT measurements were more than 0.80. CONCLUSION: Our study results prove that the modified 3D-DT, which involves the use of an eyelid hook, can be a highly reliable method for evaluating LET. Furthermore, this novel and simple method may be utilized as the basis for further investigation and routine pre- and postoperative clinical evaluation.

    Reference
    Related
    Cited by
Get Citation

Xiao-Yi Hou, Alexander C. Rokohl, Marius M. Meinke, et al. A modified 3D stereophotogrammetry-based distraction test for assessing lower eyelid tension. Int J Ophthalmol, 2022,15(11):1757-1764

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:February 16,2022
  • Revised:April 21,2022
  • Adopted:
  • Online: October 25,2022
  • Published: