Agreement of intraocular pressure measurement with Corvis ST, non-contact tonometer, and Goldmann applanation tonometer in children with ocular hypertension and related factors
Author:
Contact Author:

Yan-Hui Chen. Ophthalmic Hospital of Tanshan, Tangshan 063000, Hebei Province, China. ylxx0431@163.com; Yan-Nian Hui. Department of Ophthalmology, Xijing Hospital, Fourth Military Medical University, Xi’an 710023, Shaanxi Province, China. ynlhui@163.com

Affiliation:

Clc Number:

Fund Project:

Supported by Medical Science Research Project of Hebei Province in 2023 (No.20231818).

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    AIM: To access the agreement of intraocular pressure (IOP) values obtained from biomechanically corrected tonometer [Corvis ST (CST)], non-contact tonometer (NCT), and Goldmann applanation tonometer (GAT) in children with NCT measured-IOP (NCT-IOP) values of 22 mm Hg or more, and related factors. METHODS: A total of 51 eyes with NCT-IOP≥22 mm Hg in children aged 7 to 14y were examined and IOP was measured by CST, NCT, and GAT. Based on GAT measured IOP (GAT-IOP), ocular hypertension (OHT) group (≥22 mm Hg, 24 eyes) and the non-OHT group (<22 mm Hg, 27 eyes) were defined. We compared the agreement of the three measurements, i.e., CST measured IOP (CST-IOP), GAT-IOP, and NCT-IOP, and further analyzed the correlation between the differences in tonometry readings, central corneal thickness (CCT), axial length (AL), optic disc rim volume, and age. RESULTS: Compared with the OHT group, thicker CCT, larger rim volume, and higher differences between NCT-IOP and GAT-IOP, were found in the non-OHT group. The differences between CST-IOP and GAT-IOP were lower than the differences between NCT-IOP and GAT-IOP in both groups. The mean differences in CST-IOP and GAT-IOP were 1.26 mm Hg (95% limit of agreement ranged from 0.1 to 2.41 mm Hg, OHT group) and 1.20 mm Hg (95% limit of agreement ranged from -0.5 to 3.00 mm Hg, non-OHT group), and the mean differences in NCT and GAT were 3.90 mm Hg (95% limit of agreement ranged from -0.19 to 9.70 mm Hg, OHT group) and 6.00 mm Hg (95% limit of agreement ranged from 1.50 to 10.50 mm Hg, non-OHT group). The differences between CST-IOP and GAT-IOP were not related to CCT, age, and AL in both groups; while the differences between NCT-IOP and GAT-IOP were related to CCT in the OHT group (r=0.93, P<0.001) and to CCT and AL in the non-OHT group (r=0.66, P<0.001, r=-0.81, P<0.001). CONCLUSION: The accuracy of NCT in the diagnosis of pediatric OHT is low. The agreement of CST-IOP and GAT-IOP was significantly higher in children with and without OHT than in those with NCT-IOP and GAT-IOP. Therefore, CST can be used as a good alternative for IOP measurement in children. The impacts of CCT and AL on NCT measurement need to be fully considered when managing childhood IOP.

    Reference
    Related
    Cited by
Get Citation

Hou-Gang Li, Yan-Hui Chen, Fang Lin, et al. Agreement of intraocular pressure measurement with Corvis ST, non-contact tonometer, and Goldmann applanation tonometer in children with ocular hypertension and related factors. Int J Ophthalmol, 2023,16(10):1601-1607

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:April 23,2023
  • Revised:August 01,2023
  • Adopted:
  • Online: September 19,2023
  • Published: