A highly sensitive fluorescent probe RN-NA reveals peroxynitrite as a novel biomarker for primary open angle glaucoma
Author:
Contact Author:

Ke-Yin Liu. State Key Laboratory of Biobased Material and Green Papermaking, Key Laboratory of Pulp & Paper Science and Technology of Shandong Province/Ministry of Education, Qilu University of Technology, Shandong Academy of Sciences, Jinan 250353, Shandong Province, China. keyinliu@163.com; Yu-Hong Chen. Key Laboratory of Myopia, NHFPC (Fudan University), Shanghai Key Laboratory of Visual Impairment and Restoration (Fudan University), Shanghai 200031, China. doctorrainbow@126.com

Affiliation:

Clc Number:

Fund Project:

Supported by the National Natural Science Foundation of China (No.81870692; No.82070959; No.82271082); the Shanghai Committee of Science and Technology, China (No.20S31905800); Clinical Research Plan of SHDC (No.SHDC2020CR6029).

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    AIM: To directly quantify peroxynitrite (ONOO-) using a highly sensitive fluorescence resonance energy transfer probe RN-NA, investigate the association between ONOO- and primary open angle glaucoma (POAG), and clarify whether RN-NA could be used as a potential tool for POAG diagnosis. METHODS: Plasma and aqueous humor (AH) samples were collected from POAG patients (n=100, age: 59.70±6.87y) and age-related cataract (ARC) patients (n=100, age: 61.15±4.60y) admitted to our hospital. Next, RN-NA was used to detect ONOO- in plasma and AH samples, and the relationship between ONOO- level and POAG was analyzed using binary logistic regression. Besides, Pearson correlation analysis was applied to characterize the correlation of the levels of ONOO- with the patients’ age, intraocular pressure (IOP), and mean deviation of visual field testing. The ONOO- scavenger MnTMPyP was employed to treat the 3-morpholinosyndnomine (SIN-1)-induced ocular hypertension in mice (n=7, 6-8wk). Finally, the IOP and ONOO- in both eyes were measured 30min after the last drug treatment. RESULTS: ONOO- levels of AH and plasma were significantly higher in the POAG group than in the ARC group (P<0.01). Additionally, ONOO- levels were closely correlated with POAG in a binary logistic regression analysis [odds ratio (OR)=1.008, 95% confidence interval (CI): 1.002-1.013, P<0.01 for AH; OR=1.004, 95%CI: 1.002-1.006, P<0.001 for plasma]. Pearson correlation analysis showed that ONOO- levels in AH or plasma were positively associated with visual field defects (R=0.51, P<0.01 for AH; R=0.45, P<0.001 for plasma), and ONOO- levels in plasma and AH were correlated in the POAG group (R=0.69, P<0.001). However, administering MnTMPyP to mouse eyes reversed the elevated IOP caused by SIN-1 (P<0.05). CONCLUSION: ONOO- levels in AH and plasma, detected by RN-NA, are significantly related to POAG and positively correlated with visual field defects in POAG patients. Hence, ONOO- is a potential biomarker of POAG, especially advanced POAG. Besides, anti-nitration compounds may be novel ocular hypotensive agents based on the animal study.

    Reference
    Related
    Cited by
Get Citation

Bo Qin, Yuan Lei, Luo Bao, et al. A highly sensitive fluorescent probe RN-NA reveals peroxynitrite as a novel biomarker for primary open angle glaucoma. Int J Ophthalmol, 2024,17(2):219-227

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:July 03,2023
  • Revised:November 17,2023
  • Adopted:
  • Online: January 22,2024
  • Published: